Temperature Control Programming Procedure
OVEN SERVICE PROCEDURES
Configuration Key Functions
<FUNC> = The new setting of the selected parameter is stored
and the display advances to the next parameter. This
is required between each parameter.
= Increases the setting of the selected parameter.
= Decrease the setting of the selected parameter.
1. Open V101 switch for Basic Configuration (Figure 1)
Turn main switch to the off position
Remove instrument from its case
Open Switch V101
Re-insert the instrument back in its case.
Turn main switch to the on position
2. Basic Configurations
Using the configuration keys scroll thru parameter codes
changing them to match (Figure 2)
After P12 _._._._. Will appear
3. Close V101 switch after Basic Configuration (Figure 1)
Remove instrument from its case
Close Switch V101
Re-insert the instrument back in its case.
Error 400 will appear press and hold the and to clear
000 will appear
4. Advanced Configurations Procedure
Using the configuration keys scroll thru parameter codes
Changing them to match (Figure 3)
On the first pass thru change nnn to 311 to unlock the
advanced configuration
Scroll thru the parameter codes again and change the nnn to 5
this locks the advanced configuration
Scroll thru the parameter codes again and verify nnn is ON
SP 260˚C/500˚F
nnn 311/5
AL 315˚C/600˚F
HSA .1
Pb 4.0
ti 5.0
td .00
1P 30
C 2
rL 204˚C/400˚F
rH 310˚C/590˚F
OLH 100
tOL InF
Read the entire instruction before programming.
P1 2˚C/10˚F
P2 0
P3 315˚C/600˚F
P4 r
P5 1
P6 H.A.
P7 d
P8 OFF
P9 0
P10 100
P11 311
P12 7
Figure 2