Xlt XD-9006A (GAS Oven Version – C, AVI Hood Version – Manuel d'utilisateur Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
24
Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
Figure 5
Check Low Bias Pressure:
 Pull one of the two blue wires going into the modulating valve. (This simulates a temperature
drop and allows the oven to run at Low Flame Bias)
 If the flame goes out turn the 5mm screw clockwise 1 turn to increase Low Flame
Bias
 Wait 30 seconds and the oven will re-light.
 Using a 5mm socket turn the Low Flame Bias screw (Figure 6) until desired setting is
achieved. Use (Figure 5) for correct valve settings.
Figure 6
OVEN SERVICE PROCEDURES
Multi-Valve Adjustment Procedure
NOTE
5 mm
W/CmbarkPaW/CmbarkPa
3.5 8.75 0.875 10 25 2.5
0.2 0.49 0.049 0.2 0.49 0.049
All Oven Models
Natural Gas LP Gas
Low Flame Bias
High Flame Bias
Multi-Valve Adjustment Settings
Vue de la page 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 69 70

Commentaires sur ces manuels

Pas de commentaire