Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
HOOD SERVICE PROCEDURES
Complete VFD manual available at www.xltovens.com
Hitachi X200 Restoring Factory Defaults
Access program parameters by pressing the <FUNC> key one time and using the up and down ar-
row keys to navigate to the appropriate parameter press the <FUNC> key again to make adjust-
ments to that parameter by using the up and down arrows. To store the new settings press the
<STR> button one time.
B031 = 01
B084 = 01
After pressing the <STR> key Press and hold the <FUNC> down arrow key and <Stop/
Reset> key all at the same time. Release the keys all at once and the country code
should appear in the display (USA). Hitachi’s factory settings are now restored.
A001 = 01
A003 USA = 60 Hz. World = 50 Hz.
A082 = Supply voltage at location 200, 215, or 230 choose appropriate voltage.
A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03
Put controller into monitor mode by pressing the <FUNC> and holding until d001 appears on the
display release and then press the <FUNC> one time. The display should show 0.0.
Put the controller in Run mode by pressing the <RUN> key one time. The Run indicator light lo-
cated next to the speed control knob should illuminate.
Test run the motor by turning on one of the oven/hood switches located on the face of the hood.